DP571 Dolby
®
E Encoder User’s Manual Hardware Description
6.2.4 Main Out Connectors
The encoded Dolby E bitstream is output from the rear-panel Main Out connector as
an AES3 coaxial digital signal. Two connectors are available for transmission of
Dolby E data to multiple decoders or monitoring units.
Note: The two Main Out connectors are electrically separate, not passive loop-
through connections, so there is no need to terminate an unused output.
6.2.5 Video Ref Connectors
The DP571 requires a video reference signal to lock the audio and video at frame
boundaries.
The DP571 supports the following frame rates:
29.97 Hz
25 Hz
23.98 Hz
24 Hz (P or PsF)
30 Hz
For the 29.97 and 25 Hz frame rates, standard black burst or color bars locked to the
plant reference can be used as a video reference. All other frame rates require a Dolby
DP579 Tri-Level Sync Interface to convert tri-level reference signals into Dolby
Black (a signal similar to standard black burst that is compatible with the DP571). In
addition, vertical interval timecode (VITC) information can be extracted from a 25 or
29.97 fps composite video reference signal sent to the DP571. The video reference
can be either terminated at the loop-through connection, or passed on to additional
devices.
Note: The reference signal must be terminated with a 75 impedance on the last
device in the signal chain.
If a suitable video reference signal is not present or invalid, the:
DP571 does not encode a Dolby E bitstream.
Dolby E output on the Main Output and PCM Output are muted.
VRef LED is yellow if the wrong frame rate reference is present, and red if no
valid reference is present.