DP571 Dolby
®
E Encoder User’s Manual Setup and Status Checks
because Dolby E uses the entire audio payload of an AES pair, thereby creating the
appearance of full-scale audio on the VTR.
Note: Do not adjust the input or output volume controls when recording or playing
back Dolby E data, as this action will corrupt the data stream and render it
undecodable.
3.6 Monitoring Status Using the Status Menu
The front-panel LCD provides detailed status information on a series of status
screens. You can access the main status menu by pressing Shift then Setup at any
time, and from there you can scroll through the remaining status screens using the
right and left cursor buttons. The status screens display the device’s current status and
are not used to set values. Use the setup mode menus to set new values.
3.6.1 Main
Dolby E
5.1+2 20bit
The main screen displays the active program configuration and the bit depth. This is
the standard display for most applications.
3.6.2 External Metadata
Ext Metadata In
ENTER to View
From this status screen, pressing
Enter displays the program configuration of external
metadata, if one is present. Use the arrow keys and Enter to navigate through the
individual metadata parameters of each program. Pressing Esc returns you to the
External Metadata status screen. Use this screen to verify that the program
configuration of incoming metadata matches the program configuration being used by
the encoder.
3-5