Dolby Model DP583 Frame Synchronizer User’s Manual Front-Panel Menus
4-2
4.2 Status Displays
The main status menu appears when the unit is turned on or the Status button
combination (Shift, Setup) is pressed. Navigate through the status displays using the
arrow buttons.
4.2.1 Main Status
The top line indicates the audio format that is being received at the main input (Dolby
E, Dolby Digital, or PCM), or if No Input is being received or the unit is in Bypass.
The lower line shows additional information about the audio signal and the current
delay through the unit. Examples of the main status screen are shown below.
Dolby E
5.1+2 45msec
Dolby E Program
Configuration
Current delay
Dolby Digital
3/2L 45msec
Dolby Digital Coding Mode
indicates the number of front
and rear channels in the
stream; L indicates LFE.
Current Delay
PCM
48 kHz 45msec
Sample Rate
Current delay.
4.2.2 Buffer Stats
Buffer Stats
Drops:01 Rpts:03
Number of times a
frame of compressed
audio data has been
discarded.
Number of times a frame of
compressed audio data has
been repeated.
Press Enter to reset the counters.