Dolby Laboratories DM100 Manual de usuario Pagina 24

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 36
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 23
Dolby Model DP583 Frame Synchronizer User’s Manual Applications
3-4
Figure 3-4 Cable Turn-Around Facility
3.4 Additional Information
It is important to note that ISO/IEC 13818-1 MPEG Systems states that the audio and
video sampling clocks must be locked to the 27MHz MPEG system clock. When the
MPEG audio packet processor within the encoder/multiplexer is being presented with
an “asynchronous” pre-compressed Dolby Digital bitstream, however, the system
behavior is largely undefined.
3.5 Alarms and Monitoring
The DP583 has a bypass input that can be used for redundant or hot standby
operation. In order to connect a pair of DP583 for hot standby, the following
connections should be made.
MAIN
Vista de pagina 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 35 36

Comentarios a estos manuales

Sin comentarios