First, set the baud rate you wish to use via the System Settings
menu: Press the [Setup] button, then use the [Down] button to
step to the System Settings menu. Press [Enter] and select the
desired data rate with the [Up/Down] buttons. Press [Enter] to
save. Next, to initiate logging: Press the [Setup] button again,
then use the [Down] button to step to the I/O Control menu.
Press [Enter], then use the [Down] button to step to Logging
Output. Press [Enter] then use the [Down] button to select
Enable. Press [Enter] to start logging via the RS-232 connection
to your terminal program. See Sections 4.5 and 4.6.
Firmware Upgrade
With the DM100 powered off, press the [Power] button, then
hold down the [Setup] button. The DM100 will display the
Firmware Upgrade screen. The data transfer operates at a fixed
data rate of 115.2 kbps. If an error occurs during the upgrade,
the Error LED illuminates, an error message is displayed, and
the data transfer halts.
Pressing the [Esc] button exits the upgrade mode if data is not
being transferred, or turns the unit off if a data transfer error
occurs.
Data Transfer Error Messages:
Error Message Display Description
HDR CHKSUM ERR
Invalid checksum in file’s header.
HDR LENGTH ERR
Invalid length in file’s header.
DATA CHKSUM ERR
Invalid checksum in data portion of file.
DATA LENGTH ERR
Invalid data length specified in file’s header.
FLASH INIT ERR
Flash memory detection failed: device code not recognized.
FLASH ERASE ERR
Flash sector protected and can not be erased.
FLASH PGM ERR XX
AT ADDR YYYYYY
Flash not blank at address YYYYYY (hex). Flash module
error code given in XX (hex).
IMAGE SIZE ERR
Error in downloaded image size or address: Too large for
either RAM or flash.
VERIFY ERR
Programmed image in flash does not match downloaded
image after programming.
PRODUCT ERR
Product code in file’s header is not “DM100.”
FLASH MEM FULL
No space left in flash memory (when loading test bitstreams).
TOO MANY STREAMS
There is a limit of 200 streams in the unit.