12 Dolby
®
Media Meter 2 User’s Manual
Measuring Loudness
TomeasurefasterthanrealtimeintheAudioSuit eplugin:
1. Click
Resettorestartthemeasurements.
2. Click
Log FiletogenerateandsavealogofDolbyMediaMeter2activity.Reviewthe
defaultfilenameandlocation,andmakeanynecessarychanges.
3. Choosethedesiredmeasurementtypes,byrightclickinginameasurementboxand
choosinganotheroptionfromthecontextmenu.
3.6 File-Naming Conventions That Ensure Automatic File
Selection
DolbyMediaMeter2automaticallyselectssourcefilesetsthatfollowthesenamingrules:
1. AllthechannelIDsusedarestandard.ThechannelIDsarenotcasesensitive.
2. ThechannelIDisseparatedbeforeandafterwitheitheraperiodorunderscore.
3. ThefilenamesforthechannelsareidenticalexceptforchannelID.
4.
Thenumberoffilesmatchesthenumberofchannelsselectedintheclient
Channels
tab.
5. ThefilechannelIDsmatchthechannelIDsselectedintheclient
Channelstab.
6. Filenamesdonotcontaintheampersan d(&)character.
Thefollowingsectionsprovidefourexamplesoffilesetsthatwouldbeautomatically
selected.
Example 1
Thisfilesetusesaperiodastheseparator.
ExampleOne.L.wav
ExampleOne.R.wav
ExampleOne.C.wav
ExampleOne.LFE.wav
ExampleOne.Ls.wav
ExampleOne.Rs.wav
Example 2
Thisfilesetusesanunderscoreastheseparator.
ExampleTwo_L.wav
ExampleTwo_R.wav
Note: RememberthatProToolsalwaysinsertsbothRTASandAudioSuitepluginsas
prefader.Measurementswillnotcorrectlymatchthefinalmixedoutputifthe
meterisinsertedontheinputsectionofProToolswhenmixautomationispresent.
Caution: Filenamesincludingtheampersand(&)charactercannotbeprocessedbythe
DolbyMediaProducersuite.